SMA SUNNY ISLAND 4548-US Operating Manual page 173

Off-grid inverter
Hide thumbs Also See for SUNNY ISLAND 4548-US:
Table of Contents

Advertisement

SMA Solar Technology America LLC
232# Grid Control
No. Name
01
GdVtgMin
02
GdVtgMax
03
GdCurNom
04
GdFrqNom
05
GdFrqMin
06
GdFrqMax
07
GdVldTm
08
GdMod
09
GdRvPwr
10
GdRvTm
15
GdAlSns
37
GdVtgIncProEna Voltage increase
38
GdVtgIncPro
41
GdSocEna
Operating Manual
Description
Minimum grid voltage
Maximum grid voltage
Nominal grid current
Nominal grid
frequency
Minimum power
frequency
Maximum power
frequency
Minimum time required
for grid (voltage and
frequency) to be within
permissible range for
connection
Grid interface
Permissible grid reverse
power (active power)
Permissible time for
grid reverse power
AI sensitivity
protection
Limit for voltage
increase protection
Activate the grid
request based on SOC
Value
Explanation
GridCharge
Charging on the
utility grid
GridFeed
Charge and
feedback on the
utility grid
0 W to 5,000 W
0 sec to 60 sec
Low
Low
Medium
Medium
Normal
Normal
High
High
Disable
Disable
Enable
Enable
Disable
Disable
Enable
Enable
SI4548-6048-US-BE-en-21
19  Parameter Lists
Default
value
105.6 V
132 V
30 A
60 Hz
59.3 Hz
60.5 Hz
300 sec
GdFeed
100 W
5 sec
Normal
Disable
132 V
Disable
173

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sunny island 6048-usSunny island 4548-us-10

Table of Contents