Opening And Closing; Opening The Sunny Island - SMA SUNNY ISLAND 4548-US Operating Manual

Off-grid inverter
Hide thumbs Also See for SUNNY ISLAND 4548-US:
Table of Contents

Advertisement

SMA Solar Technology America LLC

5 Opening and Closing

The enclosure of the Sunny Island has a removable lid. Remove the enclosure lid only when installing
the device or for required maintenance or repair work.

5.1 Opening the Sunny Island

1. Stop the Sunny Island (see Section 9.2 "Stopping the Sunny Island (Standby)", page 76).
2. Disconnect the Sunny Island from voltage sources (see Section 9.4 "Disconnecting the Device
from Voltage Sources", page 76).
3. Ensure that the system cannot be accidentally switched on again.
Danger to life due to high voltages in the Sunny Island
Death or serious injury possible due to electric shock.
• Wait 15 minutes before opening the Sunny Island until its capacitors are discharged.
Risk of burns due to hot components
Some components of the Sunny Island can get very hot during operation. Touching these
components can cause burns. Heat build-up can cause burns.
• During operation, do not touch any parts other than the enclosure lid of the Sunny Island.
• When the Sunny Island is open, do not touch hot surfaces.
4. Loosen all six screws on the enclosure lid and set
them aside.
5. Remove the enclosure lid and set it aside.
☑ The Sunny Island is open.
Operating Manual
5  Opening and Closing
SI4548-6048-US-BE-en-21