Chapter 3 Removal and Replacement Procedures
Revision B
RRP6.3 TRANSFER ASSY (PL6.1.7)
[Removal]
1) Remove the CASSETTE ASSY 250. (RRP2.1)
2) Open the COVER ASSY FRONT MG (PL1.2.1).
Note: Cover the drum of the DRUM CARTRIDGE to avoid exposure to light.
3) Remove the DRUM CARTRIDGE. (RRP4.6)
Note: The FUSING part is very hot. Take added care not to get burned when performing the
service operation.
4) Remove the FUSER UNIT. (RRP6.1)
5) Remove the COVER ASSY TOP. (RRP1.1)
6) Remove the COVER ASSY WINDOW TNR. (RRP1.6)
7) Remove the COVER SIDE R. (RRP1.5)
8) Remove the COVER SIDE L. (RRP1.7)
9) Close the TRANSFER ASSY (PL6.1.7).
Note: When carrying out the work described next procedure, take care not to scratch the belt
surface of the TRANSFER ASSY.
10) Release the hooks of the COVER
HARNESS (PL6.1.8), using a miniature
screwdriver, and then remove the COVER
HARNESS.
Note: When carrying out the work described below, leave the relay connector on the TRANSFER
ASSY harness side.
3 - 163