Chapter 2 Operation of Diagnostic
Motor/Clutch/Solenoid Name
(Diag. Code)
Tray1 Feed SOLENOID
(DO-2f)
Tray2 Feed SOLENOID
(DO-31)
Epson AcuLaser C2900N
NOTE: This procedure is for the technical staff.
When performing operation for five minutes or longer with the front
cover open, remove the drum cartridge, and cover the drum to avoid
exposure to light.
1)
Remove the COVER SIDE L.
2)
Power on the printer, and enter the Diag Mode.
3)
Cheat the Safety Interlock System.
4)
Execute DO-2f.
5)
Check that the Feed Solenoid movement.
6)
Press the "STOP" key to stop the test.
7)
Remove the cheater.
8)
Replace the COVER SIDE L.
NOTE: This procedure is for the technical staff.
1)
Remove the COVER REAR OPT and COVER SIDE L OPT.
2)
Power on the printer, and enter the Diag Mode.
3)
Execute DO-31.
4)
Check that the Feed Solenoid movement.
5)
Press the "STOP" key to stop the test.
6)
Replace the COVER REAR OPT and COVER SIDE L OPT.
2 - 29
Check procedure
Cassette1 Feed Solenoid
CASSETTE2 Feed Solenoid
Revision B
Rio02018KA
Rio02056GA