Chapter 2 Operation of Diagnostic
- Checking Motor, Clutch and Solenoid
Before executing the DO test, close all covers and doors.
Motor/Clutch/Solenoid Name
(Diag. Code)
Main Motor
(DO-0/1/2)
Sub Motor
(DO-5/6/7)
Epson AcuLaser C2900N
NOTE: This procedure is for the technical staff.
When performing operation for five minutes or longer with the front
cover open, remove the drum cartridge, and cover the drum to avoid
exposure to light.
1)
Power on the printer, and enter the Diag Mode.
2)
Open the Front Cover
3)
Cheat the Safety Interlock System.
4)
Execute DO-0.
5)
Check that the Drum rotates.
Drum
Belt
6)
Press the "STOP" key to stop the test.
7)
Remove the cheater.
8)
Close the Front Cover.
1)
Power on the printer, and enter the Diag Mode.
2)
Execute DO-5.
3)
Check that the Exit Roll rotates.
Exit Roll
4)
Press the "STOP" key to stop the test.
2 - 24
Check procedure
Revision B
MiS02012SA
MiS02013SA
Confidential