Chapter 1 Troubleshooting
FIP-1.51 091-935: IOT PHD Life Over
Step
Possible causative parts:
DRUM CARTRIDGE (PL4.1.21)
PWBA MCU (PL8.2.13)
Checking the life counter value of the DRUM CARTRIDGE.
1
Does the life count value show the near of the end?
Checking after resetting the DRUM CARTRIDGE.
Reseat the DRUM CARTRIDGE.
2
Does the error still occur when the power is turned OFF
and ON?
Checking after replacing the DRUM CARTRIDGE.
Replace the DRUM CARTRIDGE. (Refer to RRP4.6.)
CAUTION: Be sure to pull eight sealing tapes out from
3
a new DRUM CARTRIDGE before installation.
Does the error still occur when the power is turned OFF
and ON?
Epson AcuLaser C2900N
Check
1 - 103
Remedy
Yes
Replace the
DRUM
Go to step 2.
CARTRIDGE.
(Refer to RRP4.6.)
Go to step 3.
End of work.
Replace the
PWBA MCU.
End of work.
(Refer to RRP8.9.)