Chapter 2 Operation of Diagnostic
Motor/Clutch/Solenoid Name
(Diag. Code)
Duplex Clutch
(DO-35)
Epson AcuLaser C2900N
NOTE: This procedure is for the technical staff.
Combination test is as follows.
The duplex gear rotates when DO-d and DO-35 are executed.
1)
Power on the printer, and enter the Diag Mode.
2)
Open the Front Cover.
3)
Cheat the Safety Interlock System.
4)
Execute DO-d and DO-35.
5)
Check that the Gear rotates.
6)
Press the "STOP" key to stop the clutch.
7)
Press the " " key to display DO-d.
8)
Press the "STOP" key to stop the motor.
9)
Remove the cheater.
10) Close the Front Cover.