Epson AcuLaser C2900N Service Manual page 178

Hide thumbs Also See for AcuLaser C2900N:
Table of Contents

Advertisement

Chapter 1 Troubleshooting
FIP-1.P17 The top margin is incorrect / The side margin is incorrect
ESS and possible causative parts
- DRUM CARTRIDGE (PL4.1.21)
- TRANSFER ASSY (PL6.1.7)
- ROS ASSY (PL4.1.1)
Before commencing troubleshooting, check the paper transfer path. Make sure there is no foreign
materials on the transfer path, such as staples, paper clips, scraps of paper and so on.
Step
Checking the printing.
1
Checked by [Test Print] - [Gradation] in diagnosis.
Is the image printed correctly?
Checking after replacing the DRUM CARTRIDGE.
Replace the DRUM CARTRIDGE. (Refer to RRP4.6.)
2
Does the error appear on the printed material when
printing?
Checking after replacing the TRANSFER ASSY.
Replace the TRANSFER ASSY. (Refer to RRP6.3.)
3
Does the error appear on the printed material when
printing?
Epson AcuLaser C2900N
Mnt05100KA
Check
Mnt05101KA
Printing data is
incorrect, then
check the printing
data which the
problem
generated.
Go to step 3.
Go to step 4.
1 - 165
Revision B
Remedy
Yes
No
Go to step 2.
End of work.
Replace the ROS
ASSY. (Refer to
RRP4.1.)
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents