14. Malfunction code
14.3.6
C002: RAM error at startup (standard memory)
14.3.7
C003: RAM error at startup (expanded memory)
MFP board (MFPB)
Step
1
Reboot the main body.
Check connection state of the standard/
2
expanded memory and correct as neces-
sary.
Check the MFPB connector for proper con-
3
nection and correct as necessary.
4
Change the standard/expanded DIMM.
5
Change MFPB
14.3.8
C013: MAC address error at startup
14.3.9
C015: BOOT ROM error at startup
MFP board (MFPB)
Step
1
Reboot the main body.
Check the MFPB connector for proper con-
2
nection and correct as necessary.
3
Change MFPB
162
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 1.0 Nov. 2007
DIMM (standard/option)
WIRING DIAGRAM
Control signal
⎯
⎯
⎯
⎯
⎯
WIRING DIAGRAM
Control signal
⎯
⎯
⎯
Location (electri-
cal component)
⎯
⎯
⎯
⎯
⎯
Location (electri-
cal component)
⎯
⎯
⎯