Field Service Ver. 1.0 Nov. 2007
11.5 SUPPLIES
11.5.1
REPLACE
A. FUSER UNIT
Function
• Resets the fuser unit counter.
Use
• To use when the fuser unit has been replaced.
Setting
1. Call the service menu to the screen.
2. Select [SERVICE MENU] → [SUPPLIES] → [REPLACE] → [FUSER UNIT], and
/procedure
select "YES."
3. Press the Menu/Select key and reset the counter.
11.6 RESTORE PASSWARD
Function
• Reinitializes the user password used for the "INTERFACE MENU / SYSTEM
DEFAULT MENU / MAINTENANCE MENU" set by user.
Use
• To reinitialize the user password when the menu cannot be opened even when enter-
ing the correct password.
• To reinitialize the user password when the user forgets the password.
YES : Initialize password
NO : Not initialize password
Setting
1. Select "RESTORE PASSWORD" and press the Menu/Select key.
/procedure
2. Select "YES" and press the Menu/Select key.
3. Return the password set at "INTERFACE MENU / SYSTEM DEFAULT MENU /
MAINTENANCE MENU" to "0000."
• The default setting is NO.
YES
11. SERVICE MENU
"NO"
145