Perkins M300TI Installation Manual page 85

Sabre marine engines
Table of Contents

Advertisement

TPD1317e
Exhaust
Exhaust gas flow
Maximum restriction
measured within(305 mm)
12" of turbocharger outlet.
Recommended pipe bore
(wet exhaust).
Minimum rise from sea
water level to exhaust
outlet centreline.
Lubricating System
Recommended lubricating
oil.
Sump capacity maximum
Maximum installation
angle plus planing
angle for continuous
operation.
Oil pressure, in operating
speed range (steady state).
Low oil pressure
switch setting.
Electrical System
Alternator (insulated)
Starter type (insulated)
Number of teeth in flywheel
Number of teeth on starter
Cold Start Limits
Minimum cold start
temperature (without aid).
Batteries for minimum
cold start
Model M92B
12.3 m
/min (434 ft
3
15 kPa (4.43" Hg, 112 mm)
76 mm (3")
203 mm (8.0")
AP1 CG4/CH4, ACEA E3/E5
7 litres (12.3 pints)
20
nose up
o
3.0 to 3.7 bar (43.5 to 54 Ibf/in
0.8 bar (12 Ibf/in
Prestolite A128E 55A (24V) or 90A (12V).
Prestolite S115 - 12 volt and 24 volt
126
-10
12 volt system - 1 off 12 volt 520 amp to BS3911
24 volt system - 2 off 12 volt 440 amp to BS3911
/min).
3
)
2
)
2
10
C
o
Chapter 11