Perkins M300TI Installation Manual page 82

Sabre marine engines
Table of Contents

Advertisement

Chapter 11
Minimum cross section of
air duct (per engine).
Exhaust
Exhaust gas flow
Maximum restriction
measured within(305 mm)
12" of turbocharger outlet.
Recommended pipe bore
(wet exhaust).
Minimum rise from sea
water level to exhaust
outlet centreline.
Lubricating System
Recommended lubricating
oil.
Sump capacity maximum
Maximum installation
angle plus planing
angle for continuous
operation.
Oil pressure, in operating
speed range (steady state).
Low oil pressure
switch setting.
Electrical System
Alternator (insulated)
Starter type (earth return)
Starter type (insulated)
Number of teeth in flywheel
Number of teeth on starter
Cold Start Limits
Minimum cold start
temperature (without aid).
Batteries for minimum
cold start
Page 78
Model M115T
174 cm
(27 sq ins)
2
temperate climates
348 cm
(54 sq ins)
2
for hot climates
16.4 m
/min (579 ft
/min).
3
3
10.2 kPa (3.0" Hg, 76 mm)
AP1 CG4, ACEA E3
7 litres (12.3 pints)
3.0 to 3.7 bar (43.5 to 54 Ibf/in
Prestolite A127 40A (24V) or 70A (12V).
Prestolite M127 - 12 volt only
Prestolite S115 - 12 volt and 24 volt
12 volt system - 1 off 12 volt 520 amp to BS3911
24 volt system - 2 off 12 volt 440 amp to BS3911
Model M92
139 cm
temperate climates
277 cm
for hot climates
15.1 m
/min (533 ft
3
88.9 mm (3.5")
76 mm (3")
203 mm (8.0")
20
nose up
o
0.8 bar (12 Ibf/in
)
2
126
10
-10
C
o
TPD1317e
(21.5 sq ins)
2
(42.9 sq ins)
2
/min).
3
)
2

Hide quick links: