M115T And M92 Engines - Perkins M300TI Installation Manual

Sabre marine engines
Table of Contents

Advertisement

Chapter 8
TPD1317e
8.4
M115T and M92 Engines
Figure 2 shows the position of both the speed selector and manual stop lever on the injection pumps fitted to
the M115T and M92 engines.
An electric stop solenoid is provided as standard equipment, but the mechanical stop lever, which is intended
for remote operation by a piano wire type cable assembly, is an alternative means of stopping the engine and
it is independent of electrical supply. The manual stop lever is, therefore, a back-up control to be used in the
rather remote eventuality of the failure of the electric stop to work. It is recommended that it is connected, with
the cable arranged so that it can be operated without opening the engine box (in case of fire)
Gearboxes supplied at the time that the engine is purchased will be fitted with connections to suit Morse 33C
cables.
Speed selector
lever
Stop
Run
Stop control
Viewed from above
Idle
Full speed
M92
M115T
Figure 2 - Speed selector lever and stop lever