Perkins M300TI Installation Manual page 79

Sabre marine engines
Table of Contents

Advertisement

TPD1317e
Exhaust
Exhaust gas flow
Maximum restriction
measured within(305 mm)
12" of turbocharger outlet.
Recommended pipe bore
(wet exhaust).
Recommended pipe bore
(dry).
Minimum rise from sea
water level to exhaust
outlet centreline.
Lubricating System
Recommended lubricating
oil.
Sump capacity maximum
Maximum installation
angle plus planing
angle for continuous
operation.
Oil pressure, in operating
speed range (steady state).
Low oil pressure
switch setting.
Electrical System
Alternator
Starter type
Number of teeth in flywheel
Number of teeth on starter
Cold Start Limits
Minimum cold start
temperature (with aid).
Batteries for minimum
cold start
Model M135
20 m
/min (706 ft
3
10.2 kPa (3.0" Hg)
76 mm (3.0")
63.5 mm (2.5")
203 mm (8.0")
AP1 CC/SE
API CD/SE or CCMC D4 can also be used but
are not recommended for first 20/40 hours
15 litres (3.3 gallons)
17
engine front up + 3
o
rise with special kit of parts, 30
280 kN/m
83 kN/m
Lucas A127 40A (24V) or 70A (12V).
CAV CA45H
-15
2 off - 315 Amps to BS3911 or
2 off - 535 Amps to SAE J537
Model M130C
/min).
3
rise. 5
nose down + 3
o
o
heel
o
(40 psi)
2
(12 psi)
2
126
10
C (5
F)
o
o
Chapter 11
o
Page 75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M225tiM265tiM215cM135: m130cM115tM92 ... Show all

Table of Contents