Page 72
Model M225Ti/M215C
35.08 m
10.2 kPa (3.0" Hg)
AP1 CD/SE CCMC D4
15 litres (3.3 gallons)
17
engine front up + 3
o
with special kit of parts, 30
2.8 to 3.8 bar (40 to 55 psi)
0.8 bar (12 psi)
Lucas A127 40A (24V) or 70A (12V).
2 off - 12V 315 Amps to BS3911 or
2 off - 12V, 535 amps to SAE J537
Model M185C
/min (1240 ft
/min).
3
3
127 mm (5.0")
100 mm (4.0")
76.2 mm (3.0")
203 mm (8.0")
rise. 5
nose down + 3
o
o
heel when motor sailing.
o
Lucas S115
126
10
-15
C (5
F)
o
o
TPD1317e
rise
o

Hide quick links: