Perkins M300TI Installation Manual page 73

Sabre marine engines
Table of Contents

Advertisement

TPD1317e
Minimum cross section
of air duct (per engine)
Exhaust
Exhaust gas flow
Maximum restriction measured
within (305mm) 12" of
turbocharger outlet
Recommended pipe bore (wet
exhaust)
Recommended pipe bore (dry)
Minimum rise from sea level to
exhaust outlet centre-line
Lubricating System
Recommended lubricating oil
Sump capacity maximum
Maximum installation angle
plus planing angle for
continuous operation
Oil pressure in operating
speed range (steady state)
Low oil pressure switch setting
Electrical System
Alternator
Starter type
Number of teeth in flywheel
Number of teeth on starter
Cold Start Limits
Minimum cold start temperature
(with aid)
Batteries for minimum
cold start
Model M300Ti
910cm
(142sq ins) for hot climates 806cm
2
455cm
(71sq ins) for temperate
2
43.1m
/min (1520ft
/min)
3
3
climates
36.4m
/min (1290ft
3
10.2kPa (3.0"Hg)
127mm (5.0")
76.2mm (3.0")
203mm (8.0")
API CF-4/SE or CCMC D5
15 litres (3.3 gallons)
17
engine front up plus 3
o
5
nose down plus 3
rise, with special kit of parts.
o
o
30
heel when motor sailing
o
2.5 to 3.5 bar (36 to 50 psi)
0.8 bar (12 psi)
Lucas A127 40 amp (24 volt) or 70 amp (12 volt)
Lucas S115
-15
2 off 12 volt - each 520 amps to BS 3911
or 2 off 12 volt - each 800 amps to SAE J537
Model M265Ti
(126sq ins) for hot climates
2
406cm
(63sq ins) for temperate
2
climates
/min)
3
rise
o
126
10
C (5
F)
o
o
Chapter 11
Page 69

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M225tiM265tiM215cM135: m130cM115tM92 ... Show all