Q24/Q48 Tape Library
PROBLEM
<Media Attention> LED issues
Contamination by loose
debris.
Non-acclimated media.
Tape cartridge is
incompatible.
Expired cleaning cartridge.
Bad/defective/contaminated
media.
Tape cartridge movement
Tape cartridge stuck in tape
drive.
Tape stuck in storage slot.
© Copyright QUALSTAR 2015
SOLUTION
Avoid contamination by ensuring that the library is installed in a clean,
contamination-free environment. Tapes should be stored vertically in
their plastic cases. Clean the tape drive(s) as needed.
A tape should be acclimated for at least 24 hours before being used,
particularly if it has been stored at a substantially different
temperature or level of humidity than the library.
Use only tapes that are compatible with the tape drive type.
See Section 2.15
Make sure you are using an Ultrium universal cleaning tape. (max. 50
cleans)
If the <Media Attention> LED is cleared and the tape drive is clean, but
the LED immediately re-displays each time a particular tape is loaded,
that tape should be suspected of being defective.
 Export the tape and load a known good tape. In some cases, a tape
can be worn out, have a defective tape memory, or have been
formatted as a Firmware Upgrade Cartridge.
 Any tape that is suspected of being defective or contaminated
should NOT be reused in any drive.
 Power cycle the library, allow it to complete initialization, which in
rare cases can take as long as 10 minutes, and then retry unloading
the tape using the library operator control panel.
 Allow the tape drive to complete all operations. This may take as
long as ten minutes if you reset or cycle power to the library while
the cartridge is positioned at the physical end of the media.
 Make sure that the backup software is not reserving the slot or
preventing the tape drive from ejecting the tape. The backup
software needs to cancel the reservation and any hold it has on the
tape drive. Temporarily disconnecting the library from the host
server and power cycling eliminates the host and its software as a
problem source.
 Contact your service representative.
See Section 4.3

Table 6 Troubleshooting

Installation and Operations Manual
68