Chapter 6 Menu Operations — Menu list
Item
[HYTRON140 NEAR
Selects the near end voltage in steps of 0.1 V when [HYTRON140] is selected in the main menu →
END]
[BATTERY SETUP] → [BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]...[15.0V]
f Factory setting: [13.1V]
[DIONIC HC NEAR END] Selects the near end voltage in steps of 0.1 V when [DIONIC HC] is selected in the main menu →
[BATTERY SETUP] → [BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]...[15.0V]
f Factory setting: [13.4V]
[ENDURA10 NEAR
Selects the near end voltage in steps of 0.1 V when [ENDURA10] is selected in the main menu →
END]
[BATTERY SETUP] → [BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]...[15.0V]
f Factory setting: [13.4V]
[PAG L96e NEAR END]
Selects the near end voltage in steps of 0.1 V when [PAG L96e] is selected in the main menu →
[BATTERY SETUP] → [BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]...[15.0V]
f Factory setting: [12.7V]
[TYPE A FULL]
Selects the voltage for full display in steps of 0.1 V when [TYPE A] is selected in the main menu →
[BATTERY SETUP] → [BATTERY SELECT].
The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.
[13.0V]...[17.0V]
f Factory setting: [15.6V]
[TYPE A NEAR END]
Selects the near end voltage in steps of 0.1 V when [TYPE A] is selected in the main menu → [BATTERY
SETUP] → [BATTERY SELECT].
The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.
[11.0V]...[15.0V]
f Factory setting: [13.2V]
[TYPE A END]
Selects the end voltage in steps of 0.1 V when [TYPE A] is selected in the main menu → [BATTERY
SETUP] → [BATTERY SELECT].
The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.
[11.0V]...[15.0V]
f Factory setting: [12.5V]
[TYPE B FULL]
Selects the voltage for full display in steps of 0.1 V when [TYPE B] is selected in the main menu →
[BATTERY SETUP] → [BATTERY SELECT].
The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.
[13.0V]...[17.0V]
f Factory setting: [15.9V]
[TYPE B NEAR END]
Selects the near end voltage in steps of 0.1 V when [TYPE B] is selected in the main menu → [BATTERY
SETUP] → [BATTERY SELECT].
The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.
[11.0V]...[15.0V]
f Factory setting: [12.9V]
[TYPE B END]
Selects the end voltage in steps of 0.1 V when [TYPE B] is selected in the main menu → [BATTERY
SETUP] → [BATTERY SELECT].
The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.
[11.0V]...[15.0V]
f Factory setting: [12.5V]
[TYPE C FULL]
Selects the voltage for full display in steps of 0.1 V when [TYPE C] is selected in the main menu →
[BATTERY SETUP] → [BATTERY SELECT].
[13.0V]...[17.0V]
f Factory setting: [15.9V]
[TYPE C NEAR END]
Selects the near end voltage in steps of 0.1 V when [TYPE C] is selected in the main menu → [BATTERY
SETUP] → [BATTERY SELECT].
[11.0V]...[15.0V]
f Factory setting: [13.2V]
[TYPE C END]
Selects the end voltage in steps of 0.1 V when [TYPE C] is selected in the main menu → [BATTERY
SETUP] → [BATTERY SELECT].
[11.0V]...[15.0V]
f Factory setting: [12.5V]
[BATT STAT NEAR END] Selects the near end percent value.
When the battery charge level percentage cannot be detected, this will follow the near end voltage value
set for [TYPE A].
[4%], [5%], [6%], [7%], [8%], [9%], [10%], [12%], [14%], [16%], [18%], [20%]
f Factory setting: [5%]
If a battery whose remaining charge is displayed in units of 10% is used, the setting value and actual near
end warning may vary slightly.
[BATT STAT END]
Selects the end percent value.
When the battery charge level percentage cannot be detected, this will follow the end voltage value set for
[TYPE A].
[1%]...[10%]
f Factory setting: [1%]
When using a battery which displays battery charge level by units of 10%, an end is determined only in two
stages: when it is set between [1%] and [5%], or when it is set between [6%] and [10%].
Description of settings
– 150 –