2.2.18
Before making the final gas connection, thoroughly purge the gas
supply pipework to remove all foreign matter, otherwise serious
damage may be caused to the gas control valve on the fire.
The other firebox fixing method is as follows :-
In installations where the cable method is not suitable (e.g. loose masonary in rear
of fire opening) the firebox can be secured to the fire surround using four screws
and wall plugs provided. Below (figure 16) is a diagram to indicate the hole centre
positions available on the firebox to facilitate the screw fixing to the fireplace /
surround.
Fig. 16
532mm
2.3
GAS TIGHTNESS AND INLET PRESSURE (MANUAL CONTROL
MODELS).
2.3.1
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
2.3.2
Turn on the main gas supply and carry out a gas tightness test.
2.3.3
Depress the control knob and turn anti-clockwise to the position marked
pilot. Hold in the control knob for a few seconds to purge the pipe work
then press the igniter button. The burner should light, continue to hold
the control knob for a few seconds then turn to the full-on position.
Check that the gas pressure for Natural Gas (G20) models is 20.0 mbar
2.3.4
(+/- 1.0mbar) 8.0 in w.g.(+/- 0.4 in w.g.)
2.3.5
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.