Gas Tightness And Burner Pressure - Flavel Atlanta FBFR MN Series Installation And Maintenance Instructions Manual

Radiant balanced flue gas fire
Table of Contents

Advertisement

Fig. 15

2.10 GAS TIGHTNESS AND BURNER PRESSURE.

a)
Remove the pressure test point screw from the inlet elbow and fit a manometer.
b)
Turn on the main gas supply and carry out a gas tightness test.
c)
Depress the control knob and turn anti-clockwise to the position marked pilot. Hold in the
control knob for a few seconds to purge the pipe work then press the igniter button. The
burner should light, continue to hold the control knob for a few seconds then turn to the full-
on position.
d)
Check that the gas pressure is 20.0 mbar +/- 1.0mbar (8.0 in w.g. +/- 0.4 in w.g.)
e)
Turn off the fire, remove the manometer and refit the pressure test point screw. Check the
pressure test point screw for gas tightness with the appliance turned on using a suitable
leak detection fluid or detector.