Centsys D5-Evo Installation Manual page 43

Light-industrial sliding gate operator
Hide thumbs Also See for D5-Evo:
Table of Contents

Advertisement

Autoclose override
It is possible for the user to temporarily turn off Autoclose when the Mode of
Operation is Standard or Reversing. To activate Autoclose Override, the
Trg input must be activated and maintained for a period longer than the time
set for the Autoclose Override time.
The gate response will be to start opening on the Trg (trigger), and then to
stop as soon as the Autoclose Override feature is activated. On clearing of
the Trg input, the gate will continue opening until fully open. The Autoclose
feature is now off and the gate will remain open indefinitely.
The next signal received on Trg will clear the Autoclose Override feature,
close the gate, and set the Autoclose feature back to normal.
Autoclose advanced options
The conditions under which the gate will automatically close can be set within
the Advanced Autoclose options menu:
Autoclose on open - automatically close the gate if it has reached the fully
open position
Autoclose on partly open - automatically close the gate if it is stopped
while opening, but before reaching the fully opened position
Autoclose on partly closed - automatically close the gate if it is stopped
while closing, but before reaching the fully closed position
More than one advanced option can be selected
Menu 4 - Modes of Operation
It is possible to select the following Modes of Operation: Standard,
Condominium, Reversing, PLC and Deadman Control Mode (DMC). All
modes are triggered by closing a normally-open contact between the Trg input
terminal and the Com terminal.
Standard mode
When stationary, a trigger impulse on Trg will cause the gate to either open or
close. On a moving gate, a trigger impulse on Trg will stop the gate. The next
impluse on Trg will cause the gate to reverse its direction of travel, i.e. the
action is start-stop-reverse.
Condominium mode
A trigger impulse on Trg will open the gate under all conditions. If it were
closing, it will stop and reverse to open. In this Mode of Operation, the only
way to close the gate is with the Autoclose feature, which is automatically
activated when Condominium mode is selected.
Reversing mode
A trigger impulse on Trg will reverse the direction of a moving gate. If it were
closing, it will stop and immediately begin opening. If it were opening, it will
stop and immediately begin closing.
PLC Mode
A trigger impulse on FRX (NO) will cause the gate to open. A trigger
impulse on the Trg (NO) will cause the gate to close
A trigger impulse on the Lck/Stp (NC) will cause the gate to stop
page 41

Hide quick links:

Advertisement

Table of Contents
loading