Buzzer Feedback - Centsys D5-Evo Installation Manual

Light-industrial sliding gate operator
Hide thumbs Also See for D5-Evo:
Table of Contents

Advertisement

Buzzer feedback

A warning buzzer will sound (where applicable) as per the table below:
Inhibitor
name
Break-in alarm
Ambush alarm
Battery low
Multiple collision
Auxiliary overload
Holiday Lockout
Emergency stop
Time-barring
No limits set
Mains failure
Beams broken
(any)
Beams failure
DOSS
disconnected
Fuse blown
Motor
disconnected
Bridge
damaged
Gate
stalled
No magnet
detected
*
Gate will close fully and then shutdown for two minutes
Number
Priority
of beeps
Continuous tone
1
for 30 seconds
Continuous tone
2
until IRBs are cleared
3 beeps periodically
4
for 30 seconds
Periodic until condition
is cleared by user
3
(500/500ms)
5 beeps periodically
5
for 30 seconds
1 beep periodically
6
for 30 seconds
1 beep periodically
7
for 30 seconds
1 beep periodically
8
for 5 seconds
3 short beeps for
9
5 seconds
2 beeps periodically
10
for 30 seconds
1 beep periodically
11
for 30 seconds
5 beeps periodically
12
for 30 seconds
5 beeps periodically
13
for 30 seconds
5 beeps periodically
14
for 30 seconds
5 beeps periodically
15
for 30 seconds
5 beeps periodically
16
for 30 seconds
4 beeps periodically
17
for 10 seconds
Periodic while
gate runs
18
(500/500ms)
Fault
type
Alarm
Alarm
Power system
fault
Collision
Hardware
User
User
User
Lost
Power system
fault
User
Hardware
Hardware
Hardware
Hardware
Hardware
Collision
Lost
page 58
Gate
User can
continues
correct
to operate
error
N/A
N/A
N/A
N/A
Yes*
Yes
Yes
No
No
No
Yes
No
No
Yes
No
Yes
No
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Yes
No
Yes
No
No
No
Yes
Yes
Yes

Hide quick links: