FIELDBUS CONNECTIONS
6.2 ETHERNET INTERFACE (OLDER MODELS)
The RJ45 connector is only available for older DS6400 Ethernet models and allows the
Ethernet connection between the host and the reader.
This interface and the connector pinout (see the following table) are IEEE 802.3 10 BaseT
and IEEE 802.3u 100 Base Tx compliant.
Pin
1
2
3
6
4, 5, 7, 8
In order to meet EMC requirements:
use Ethernet shielded cable
connect the Ethernet interface cable shield to the plant earth ground
The cable shield must be connected to the chassis of both connectors.
A ferrite (type Stewart 28A2029-0A0) may also be applied on the scanner
side of the Ethernet cable to reduce electrical noise.
NOTE
Figure 79 – DS6400 RJ45 Female Modular Connector
RJ45 Modular Jack Pinout
Name
TX +
TX -
RX +
RX -
N.C.
Function
Transmitted data (+)
Transmitted data (-)
Received data (+)
Received data (-)
Not connected
6
59