Datalogic DS6400 Reference Manual page 29

Hide thumbs Also See for DS6400:
Table of Contents

Advertisement

INTRODUCTION
7. At the last step in the sequence the display prompts to place a barcode label
centered onto the physical X position (X Offset) on the conveyor. Press the ENT
(enter) key to Continue. You have 2 minutes to read the code before the procedure
ends automatically. Be careful that the barcode is not accidentally read in the act of
placing it at the desired X Offset position, and assure that it is read by only one
scanner (see the figure below). After placing the barcode label on the X coordinate,
you may have to pass your hand or other opaque object over it to end this step.
Pressing the ▼ (down arrow) key at any point will terminate the procedure without
saving the Absolute X position alignment.
Before resetting the Master scanner, if desired, you can download the Auto
PackTrack Report file from the Master scanner RAM by connecting it to
Genius™ and using the Tools>File transfer... menu. See Help On-Line.
NOTE
8. Manually reset the Master scanner.
Figure 8 - X Offset Selection
1
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx6400

Table of Contents