Datalogic DS6500 Series Installation Quick Reference

Datalogic laser scanner installation quick reference manual
Hide thumbs Also See for DS6500 Series:

Advertisement

Quick Links

DS6500
INSTALLATION QUICK REFERENCE

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic DS6500 Series

  • Page 1 DS6500 INSTALLATION QUICK REFERENCE...
  • Page 2: Table Of Contents

    CONTENTS DS6500-100-010 MASTER/SLAVE MODEL ...1 DS6500-100-011 PROFIBUS MODEL...8 DS6500-100-012 ETHERNET MODEL ...13 DS6500-100-015 DEVICENET MODEL...18 DS6500-105-0XX OSCILLATING MIRROR MODEL...23 COMMON FEATURES ...25 For further details on product installation, see the complete Reference Manual available on the configuration CD-ROM included with this product.
  • Page 3: Ds6500-100-010 Master/Slave Model

    Laser Beam Output Window Power On LED (Red) Main/Aux. Interface 25-pin D-sub Male Connector LCD Display Lonworks 9-pin Male Connector Lonworks 9-pin Female Connector DS6500 - X0X - 0YY OPTICAL FEATURES Light Receiver Wavelength Safety Class Baud Rate Laser Control...
  • Page 4: Electrical Connections

    Optical encoder kit + 10 m cable Electrical Connections: The DS6500 reader provides a 25-pin male D-sub connector for connection to power supply, Host interface (Main and Aux), and input/output signals. Two 9-pin connectors provide access to the scanner’s local Lonworks network used for both input and output connections to build a multi-sided or omni-station system.
  • Page 5: Network Termination

    Lonworks line (polarity insensitive) Network Termination: When building a local Lonworks system the network must be properly terminated by positioning a BTK-6000 terminator on the DS6500 master reader (BTK-6000 female side) and on the last slave reader (BTK-6000 male side). to Master...
  • Page 6 *P.S. PWR-120 Main Serial Interface P.S. (Presence Sensor) connected to External Trigger/PS input. Point-to-Point Layout C-BOX 100 PG6000 Pass Through Layout *P.S. *P.S. DS4600A C-BOX 100 Local Host Auxiliary Serial Interface DS6500 MASTER/SLAVE MODEL Local Host Gryphon DS4600A C-BOX 100...
  • Page 7 Main Serial Interface P.S. (Presence Sensor) connected to External Trigger/PS input. Multiplexer Layout *P.S. DS4600A C-BOX 100 C-BOX 100 RS232 Master/Slave Layout CAB-600X *P.S. PWR-120 C-BOX 100 Auxiliary Serial Interface DS6500 MASTER/SLAVE MODEL DS4600A PWR-120 MX4000 Local Host C-BOX 100 Local Host...
  • Page 8 Local Lonworks Network CAB-60XX C-BOX 100** *P.S. Small Synchronized Network with 2 Readers Local Lonworks Network Slave 1 Master BTK-6000 CAB-610X CAB-600X CAB-610X Slave 4 Slave 3 CAB-63XX DS6500 MASTER/SLAVE MODEL Encoder*** Local Host C-BOX 100** *P.S. Encoder*** Host CAB-63XX PWR-240...
  • Page 9 P.S. (Presence Sensor) connected to External Trigger/PS input. Encoder connected to IN2/ENC input. Large Synchronized Network with DX6X00 and DS6XXX Scanners DS6500 MASTER/SLAVE MODEL Large Synchronized Network...
  • Page 10: Ds6500-100-011 Profibus Model

    Laser Beam Output Window Profibus 9-pin Female Connector (white) Power On LED (Red) LCD Display Lonworks 9-pin Female Connector Main/Aux. Interface 26-pin D-Sub Male Connector DS6500 - X0X - 0YY OPTICAL FEATURES Light Receiver Wavelength Safety Class Baud Rate Laser Control...
  • Page 11 Optical encoder kit + 10 m cable Electrical Connections: The DS6500 Ethernet reader provides a 26-pin male D-sub connector for connection to power supply and input/output signals. An Ethernet connector is used for connection to the remote Host (for ex. Remote PC connected via Internet), while a local Lonworks 9-pin female connector connects the Ethernet master to the first slave reader of the system.
  • Page 12 Supply voltage – positive pin 23, 25, 26 GND Supply voltage – negative pin RS232 GND_ISO For 20 mA C.L. connections, GND is the same of the scanner power supply. Name Function Cable shield internally connected CHASSIS by capacitor to chassis Supply voltage –...
  • Page 13 Main Serial Interface P.S. (Presence Sensor) connected to External Trigger/PS input. Point-to-Point Layout Fieldbus Network C-BOX 100 CAB-601X *P.S. Pass Through Layout *P.S. C-BOX 100 C-BOX 100 Auxiliary Serial Interface DS6500 PROFIBUS MODEL Remote Host PG6000 *P.S. Gryphon DS4600A DS4600A C-BOX 100...
  • Page 14 The Slave scanners are Master/Slave models, which allow Lonworks network propagation. **** Encoder connected to IN2/ENC input. Local Lonworks Network Fieldbus Network Master C-BOX 100** CAB-60XX CAB-610X CAB-63XX Slave 3*** CAB-63XX Fieldbus Small Synchronized Network DS6500 PROFIBUS MODEL Remote Host P.S.* Encoder**** PWR-240...
  • Page 15: Ds6500-100-012 Ethernet Model

    Laser Beam Output Window RJ45 Modular Connector for Ethernet Interface Power On LED (Red) LCD Display Lonworks 9-pin Female Connector Main/Aux. Interface 26-pin D-Sub Male Connector DS6500 - X0X - 0YY OPTICAL FEATURES Light Receiver Wavelength Safety Class Baud Rate...
  • Page 16 Optical encoder kit + 10 m cable Electrical Connections: The DS6500 Ethernet reader provides a 26-pin male D-sub connector for connection to power supply and input/output signals. An Ethernet connector is used for connection to the remote Host (for ex. Remote PC connected via Internet), while a local Lonworks 9-pin female connector connects the Ethernet master to the first slave reader of the system.
  • Page 17 Supply voltage – positive pin 23, 25, 26 GND Supply voltage – negative pin RS232 GND_ISO For 20 mA C.L. connections, GND is the same of the scanner power supply. Name Function Cable shield internally connected CHASSIS by capacitor to chassis Supply voltage –...
  • Page 18 Main Serial Interface P.S. (Presence Sensor) connected to External Trigger/PS input. Point-to-Point Layout Fieldbus Network C-BOX 100 CAB-601X *P.S. Pass Through Layout *P.S. C-BOX 100 C-BOX 100 Auxiliary Serial Interface DS6500 ETHERNET MODEL Remote Host PG6000 *P.S. Gryphon DS4600A DS4600A C-BOX 100...
  • Page 19 The Slave scanners are Master/Slave models, which allow Lonworks network propagation. **** Encoder connected to IN2/ENC input. Local Lonworks Network Fieldbus Network Master C-BOX 100** CAB-60XX CAB-610X CAB-63XX Slave 3*** CAB-63XX Fieldbus Small Synchronized Network DS6500 ETHERNET MODEL Remote Host P.S.* Encoder**** PWR-240...
  • Page 20: Ds6500-100-015 Devicenet Model

    Laser Beam Output Window Power On LED (Red) Main/Aux. Interface 26-pin D-sub Male Connector LCD Display Lonworks 9-pin Female Connector DeviceNet 5-pin Male Connector DS6500 - X0X - 0YY OPTICAL FEATURES Light Receiver Wavelength Safety Class Baud Rate Laser Control...
  • Page 21 Optical encoder kit + 10 m cable Electrical Connections: The DS6500 DeviceNet reader provides a 26-pin male D-sub connector for connection to power supply and input/output signals. A DeviceNet connector is used for connection to the remote Host, while a local Lonworks 9-pin female connector connects the DeviceNet master to the first slave reader of the system.
  • Page 22 The power supplied on pin V+ and V- is used only to propagate power to the section of the DeviceNet board directly connected to the Bus. It is completely isolated from the DS6500 power which must be supplied on pin 9, 13 and pin 23, 25 of the 26-pin Main/Aux connector.
  • Page 23 Main Serial Interface P.S. (Presence Sensor) connected to External Trigger/PS input. Point-to-Point Layout Remote Host Fieldbus Network C-BOX 100 CAB-601X *P.S. PG6000 Pass Through Layout *P.S. DS4600A C-BOX 100 C-BOX 100 Auxiliary Serial Interface DS6500 DEVICENET MODEL *P.S. Gryphon DS4600A C-BOX 100...
  • Page 24 The Slave scanners are Master/Slave models, which allow Lonworks network propagation. **** Encoder connected to IN2/ENC input. Local Lonworks Network Fieldbus Network Master C-BOX 100** CAB-60XX CAB-610X CAB-63XX Slave 3*** CAB-63XX Fieldbus Small Synchronized Network DS6500 DEVICENET MODEL Remote Host P.S.* Encoder**** PWR-240...
  • Page 25: Ds6500-105-0Xx Oscillating Mirror Model

    When the oscillating mirror is programmed to read barcode labels at very small angles, position the reader to assure at least 10° for the Skew angle (see DS6500 Reference Manual). This angle refers to the most inclined or external laser line, so that all other laser lines assure more than 10° Skew. This avoids the direct reflection of the laser light emitted by the reader.
  • Page 26 –2.5° and +37.5°. The scanner can be tilted in order for the 17.5° software setting to correspond with the 0° horizontal plane. These models provide higher scanning speed (1200 scans/sec) compared to standard models and the reading performance is not adversely effected by the oscillating mirror.
  • Page 27: Common Features

    COMMON FEATURES C-BOX 100 Pinout for DS6500: The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the DS6500 reader is connected in a network by means of the C-BOX 100: 1, 3, 5...
  • Page 28: Mechanical Installation

    Mechanical Installation: The DS6500 reader can be positioned and installed in the best way possible as a result of the Step-A-Head feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connector panels, while keeping the optic head in the correct reading position.
  • Page 29: Typical Installations

    Typical Installations: Standard Installation The DS6500 scanner is mounted on the ST-237 106° mounting bracket which guarantees a built-in Skew angle (S in the figure below) of 16° with respect to the frame plane (typically the Skew angle should be between 10°...
  • Page 30 Conveyor Speed (m/s) 0.25 0.30 0.33 2/5 Interleaved 0.38 Code Resolution (mm) 0.50 0.72 1.00 Ratio 3:1 Conveyor Speed (m/s) 0.25 0.30 0.33 Code 39 0.38 Code Resolution (mm) 0.50 0.72 1.00 Ratio 3:1; Interdigit = Module Size Conveyor Speed (m/s) 0.25 0.30 0.33...
  • Page 31: Reading Diagrams

    CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° (in) (cm) DS6500-100-0XX 0.25 mm (10 mils) DS6500-105-0XX 0.25 mm (10 mils) COMMON FEATURES (in) (cm) 0.375 mm...
  • Page 32 CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° (in) (cm) DS6500-200-0XX DS6500-205-0XX COMMON FEATURES (in) (cm) 0.5 mm (20 mils) 0.375 mm (15 mils)
  • Page 33: User Interface

    How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC RS232 COM port connections. 25-pin D-sub female DS6500 Trigger RS232 PC-side connections 25-pin male connector Name...
  • Page 34: Laser Safety

    Laser Safety Label Identification Label The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations. Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light.
  • Page 35 This product is intended to be installed by Qualified Personnel only. All DS6500 Models: This device is intended to be supplied by a UL Listed Power Unit marked “Class 2” or LPS power source which supplies power directly to the scanner via the 25/26-pin connector. WEEE Compliance LASER LIGHT...
  • Page 36 Gerät bescheinigt, daß das Gerät declare que el declare que el DS6500-XXX-XXX, Laser Scanner DS6500-XXX-XXX sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: der nachstehend angeführten Direktiven des Europäischen Rats:...

Table of Contents