9
3. By selecting the "PackTrack Calibration" option a further dialog box appears allowing to
start calibration:
Position 1
Position 2
Position 3
4. Place the code at one of the desired positions on the scan line (i.e. Position 1).
5. Measure the X, Y and Z coordinates relative to the center of the code and enter them
into the corresponding edit boxes.
In the vast majority of systems the x and z data are not necessary. For
these cases set x = 0, z= 0 during the calibration procedure.
NOTE
6. Press the Calibrate button for Position 1 to start the calibration.
98
Figure 111 – Performing the PackTrack™ Calibration