QUICK REFERENCE GUIDE This manual illustrates Local Lonworks network applications. For other types of installations, such as ID-NET™, Pass-Through, Multiplexer Layout, etc., refer to the DS6400 Reference Manual available on the CD. For complete scanner configuration using the Genius™ configuration program refer to the Help On Line.
Page 3
DS6400 QUICK GUIDE DS6400 GENERAL VIEW Standard Figure A Laser Beam Output Window Laser Safety Label Ethernet DeviceNet Figure B Laser Beam Output Window Laser Safety Label Profibus Figure D Lonworks 9-pin Male Connector Lonworks 9-pin Female Connector Serial Interface and I/O 25-pin (26-pin) male Connector...
Page 4
DS6400 QUICK GUIDE CONNECTIVITY Examples of the most common system layouts are shown in this section, for additional layouts refer to the Reference Manual. Local Lonworks Networks CAB-Sxx CBX100** CAB-610x BT-6000 Local Host Master I/O, AUX Slave 1 P.S.* BT-6000 PWR-120 P.S.
NETWORK TERMINATION When building a local Lonworks system the network must be properly terminated by positioning a BT-6000 terminator on the DS6400 master reader (BT-6000 female side) and on the last slave reader (BT-6000 male side). to Master to Slave...
The details of the connector pins are indicated in the following tables: The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this pinout when the DS6400 reader is connected by means of the CBX100/CBX500: CBX100/500 Terminal Block Connectors...
Page 7
DS6400 QUICK GUIDE The DS6400 scanner provides a 25-pin (26-pin for Fieldbus models) male D-sub connector for connection to power supply, Host interface (Main and Aux), and input/output signals. 25-pin / 26-pin D-Sub Connector Pinout Name Function Chassis - internally connected to GND...
Page 8
The power supplied on pin V+ and V- is used only to propagate power to the section of the DeviceNet board directly connected to the Bus. It is completely isolated from the DS6400 power which must be supplied on pin 9, 13 and pin 23, 25 of the 26-pin Main/Aux connector.
DS6400 QUICK GUIDE APPENDIX TECHNICAL FEATURES ELECTRICAL FEATURES Supply Voltage 15 to 30 Vdc Power Consumption 1.0 to 0.5 A; 15 W typical 1.5 to 0.7 A; 24 W Max. (including startup current) Common Communication Interfaces Main Baud Rate RS232...
113x180x104.5 (4.33x4.45x3.9) (4.45x7.08x4.11) Weight 1.5 kg (3.3 lb) 2.0 kg (4.4 lb) MODEL DESCRIPTION DS6400 - 10X - 0YY Decoder Model (Base) Optical Model (Head) 10 = Master/Slave 0 = Standard 11 = Profibus 5 = Oscillating Mirror 12 = Ethernet...
Page 11
Mounting bracket kit (5 pcs) for multisided stations 890001020 * DS6400 application software does not support any of the CBX500 Host Interface Module accessories nor the BM150 Display accessory. Use the CBX800 Gateway for Host Interface Applications, (Fieldbus and non...
Page 12
When the oscillating mirror is programmed to read barcode labels at very small angles, position the reader to assure at least 10° for the Skew angle (see DS6400 Reference Manual). This angle refers to the most inclined or external laser line, so that all other laser lines assure more than 10° Skew. This avoids the direct reflection of the laser light emitted by the reader.
Page 13
DS6400 QUICK GUIDE The mirror can be deflected up to 40°. Oscillation with respect to the output window median axis is asymmetrical (see figure below). 40° 0° Oscillating Mirror Maximum Aperture and Asymmetry By configuring the oscillating speed up to the maximum value of 19 Hz, raster emulation can be performed for reading fast moving objects.
DS6400 QUICK GUIDE MECHANICAL INSTALLATION The DS6400 reader can be positioned and installed in the best way possible as a result of the patented Step-A- Head feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connector panels, while keeping the optic head in the correct reading position.
Page 15
16° Skew Positioning The DS6400 scanner is mounted on the ST-237 106° mounting bracket which guarantees a built-in Skew angle (S in the figure below) of 16° with respect to the frame plane (typically the Skew angle should be between 10° - 20°).
FLASH™ Dynamic Focus: The DS6400 has an innovative linear motor designed to control the focus position of the scanner via software. This dynamic system, called FLASH™, is able to move the focus position rail to rail, from the minimum position to the maximum position.
DS6400 QUICK GUIDE READING DIAGRAMS In the following reading diagrams (0,0) is the center of the laser beam output window. DS6400-100-0XX – Resolution: 0.20 mm/8 mils 38 40 (in) (cm) 85 90 95 100 Global Reading Area CONDITIONS Code = Interleaved 2/5 or...
DS6400 QUICK GUIDE COMPLIANCE See the DS6400 Reference Manual for the Declaration of Conformity. LASER SAFETY Figure A Figure B Laser Beam Output Window Laser Safety Label Laser Beam Output Window Laser Safety Label The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations.
FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.