45° Skew Positioning - Datalogic DS6400 Reference Manual

Hide thumbs Also See for DS6400:
Table of Contents

Advertisement

2
2.3.2
45° Skew Positioning
The DS6400 scanner is mounted on the ST-210 90° mounting bracket (see Figure 14). By
adjusting the mounting bracket guides, reach 45° for the Skew angle (S in the figure below)
to avoid the direct reflection of the laser light emitted by the scanner:
If using the 45° Skew installation, the scanner reading performance is not
guaranteed to match that measured for the standard installation with Skew
angle between 10° - 20° (see reading diagrams in par. 9.5).
CAUTION
The ST-210 mounting bracket is an accessory of the DS6300 standard
model available in the US-60 kit (890001020).
NOTE
24
45°
Figure 23 – 45° Skew Installation
DS6400 REFERENCE MANUAL
S