Datalogic DS6400 Reference Manual page 81

Hide thumbs Also See for DS6400:
Table of Contents

Advertisement

TYPICAL LAYOUTS
The following image shows a system consisting of five readers (mixed 8K and 6K) where the
external signals (trigger, encoder, serial to host, etc.) are connected to the master through
the CBX100.
Note: In a mixed 8K and 6K family scanner network, only the 8K family scanner can be
Master.
The entire system is powered by the PWR-240 where:
Power is distributed through two CAB-63xx cables to avoid excessive current draw.
the master is connected to the CBX100 through the CAB-F0x, and provides power to the
PS and Encoder.
The Master DS8100A is terminated with the BTK-8102 and the last slave DS6400 is
terminated with the BT-6000.
CAB-610x
Slave 3
Slave 2
CAB-610x
CAB-63xx
*
P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
**
CBX100 jumper set to accept scanner power.
***
Encoder connected to Input 2 (Encoder) input.
Figure 85 –Synchronized Network with DS8100A Master and 6K Family Slaves - Serial Host
If a single power source is used, it is not necessary to separate groups of
scanners with CAB-611x "no power" cables.
NOTE
BT-6000
Slave 4
Master
Slave 1
CAB-650x
CBX100**
I/O, AUX, Encoder***
CAB-F0x
BTK-8102
CAB-63xx
7
Local Host
P.S.*
PWR-240
65