CUSTOM CABLE ELECTRICAL CONNECTIONS
4.1 POWER SUPPLY
The supply voltage for correct operation of the scanner must be between 15 and 30 VDC.
The max. power consumption is 24 W including startup current.
Datalogic strongly recommends a minimum 24 Vdc supply voltage when using a
master/slave configuration. Several accessory power supplies are available to power the
DS6400 and reading station components. See par. 1.8.
A security system allows the laser to activate only once the motor has reached the correct
rotational speed; consequently, the laser beam is generated after a slight delay from the
power on of the scanner.
DS6400 scanners have power ground GND (25/26-pin connector pin 23, 25, 26) as well as
the cable Shield (25/26-pin connector pin 1) internally connected to the chassis.
4.2 MAIN SERIAL INTERFACE
The main serial interface is compatible with the following electrical standards:
RS232
RS485 full-duplex
RS485 half-duplex
The main interface type and the relative parameters (baud rate, data bits, etc.) can be
set using the Genius™ utility program or the Genius™ based Host Mode Programming
procedure. For more details refer to the section "Main Serial Port" in the Genius™
Help On Line.
DS6400
9/13
23/25
1
Chassis
Figure 54 – Power Supply Using the 25/26-pin Connector
USER INTERFACE
VS
V+ (20 – 30 Vdc)
GND
V- (Ground)
CHASSIS
Earth Ground
4
43