9
3. The Absolute X coordinate requires placing a barcode label centered onto the physical X
position (X Offset) on the conveyor (previously set in the dialog box), you have 2 minutes
to read the code before the procedure ends automatically.
Be careful that the barcode is not accidentally read in the act of placing it at
the desired X Offset position, and assure that it is read by only one
scanner (see the figure below). You may have to pass your hand or other
opaque object over it in order to end this step.
NOTE
4. When you have successfully completed the procedure, (all scanners are green), press
the Stop button to end the procedure and return to the Auto PackTrack setup window.
The Stop button is always present and can be used at any time to end the
procedure and return to the Auto PackTrack setup window.
NOTE
At this point you can download the Auto PackTrack Report file saved in the
Master scanner RAM. This can only be done by connecting the Master to
another instance of Genius™ on a different communication channel. Select
the Tools>File transfer... menu from this new Genius™ connection.
NOTE
5. From the original Genius™ connection, press the Exit button to exit the Addon.
The calibrated values for the reading station will be sent to the Master scanner and the
Master scanner will reset the reading station which is now calibrated and ready.