Installation space

Install on a level floor which meets the following
condition.
It has enough strength to support the weight of
the printer and the stand.
For the weight of the printer and the stand,
refer to the Operation Manual.
Minimum height:1,550mm
650mm
VJ-2638: 3,708 mm
VJ-1638:2,698mm
VJ-2638: 5,358 mm
VJ-1638:4,348mm
4.2

Installation procedure

Install this product to the installation place in
accordance with the list shown below.
Please check that the butterfly bolts are not loose
before/after carrying this product.When transferring
or carrying outside, separate the printer and the
stand.
11
Check that the eight butter fly bolts
attaching the stand and the printer are not
loose.
11
Carry the printer to the installation place.
21
Turn the following adjusters in the direction
as shown below to prevent the printer from
moving.
Adjusters : 4 locations
No1
Name
No1
1
Adjuster
2
Stand
41
Confirm that the waste fluid valve is closed.
No1
Name
1
Waste fluid valve
51
Check that the eight butterfly screws (8
pieces) attaching the stand and the printer
are not loose.
5.
Connecting the power
cable
This section explains how to connect the power
cable.
Follow the steps below to connect the power
cable.
Be sure to use the specified power
cable (separately sold).Using power
cables other than the specified can
cause an electric shock or re.
U s e a p o w e r c o r d s e t w h i c h
i s c o m p a t i b l e w i t h t h e s a f e t y
1,000mm
standards, power supply voltage,
and plug shape used in the country
where this printer is used.
Us e a p owe r co rd s e t w h i c h i s
equipped with a protective earth,
and securely connect it to the outlet.
Do not use a damaged power cable.
It may cause an electric shock or re.
11
Confirm that the product is turned OFF.
11
Connect the power cables to the AC inlets
on the rear of the product.
VJ-2638: 3 locations
VJ-1638: 2 locations
VJ-1638W: 1 location
Name
No1
1
AC inlet
No1
1
AC inlet
Name
No1
Name
2
Power cable
Name
No1
Name
2
Power cable
5
VJ-2638/1638/1638W Installation Manual
21
Correctly insert the power cable plug into
the power socket.
To use the two power cables plugged in
the inlets, total capacity described below is
required. If the power source cannot supply
the required capacity, plug the two or more
power cables in the different power sources
respectively.
VJ-2638:
at "EcoMode": 26A or more
at "Powerful": 30A or more
VJ-1638: 19A or more
No1
Name
No1
1
Power cable
Name
VJ1638xE-I-03