Replacement Procedure 4-63 Humidity Sensor Module
Remove the connector. 5-22 HOLDER_PAPER_L is assembled with the hook.
It can be removed by removing hook.
Note) Putting too much force on the hook can damage it.
Replacement Procedure 4-64 Paper Sensor PCB
①Connector 1 place ( refer to Wiring Diagram 6)
②4-23 cover_cable is assembled with the hook.
Note) Putting too much force on the hook can damage it.
③Slide the 4-1 Holder_Paper_End_Under and remove it.
④4-64 Paper Sensor PCB is assembled with the hook.
Hook
Hook
Mecha Flame L Assy
Mecha Flame R Assy
27
Hook