Installing The Dehumidifier Heaters (Service Part) - Kyocera Mita KM-3530 Service Manual

Hide thumbs Also See for KM-3530:
Table of Contents

Advertisement

5FF

1-2-2 Installing the dehumidifier heaters (service part)

Dehumidifier heater installation requires the following parts:
Two (2) dehumidifier heaters (P/N 33960020): for 220 – 240 V specifications only
Two (2) dehumidifier heaters (P/N 34860030): for 120 V specifications only
Two (2) dehumidifier heater retainers (P/N 5A707690)
Six (6) M4 × 6 IT tap-tight (S-tight) screws (P/N 37611570)
Relay wire (P/N 5A707890)
Ten (10) wire saddles (P/N M2109000)
Procedure
1. Remove the two screws from each of the deck
right cover and deck left cover and then the
covers.
2. Remove the three screws holding the deck
rear cover and then the cover.
3. Open the large paper deck.
4. Remove the two screws holding the deck
paper conveying unit assembly and then the
assembly.
5. Fit the dehumidifier heaters to the dehumidifier
heater retainers using the two screws and wire
saddle for each.
6. Fit the dehumidifier heater retainers to the left
and right of the large paper deck using one
screw for each.
7. Pull the dehumidifier heater cable out to the
machine rear through the cable hole.
1-2-2
Deck paper conveying
unit assembly
Dehumidifier heater
Screws
Wire saddle
Dehumidifier heater retainer
Machine left
Screw
Figure 1-2-2
Dehumidifier heater retainer
Screw
Dehumidifier heater
Machine right
Figure 1-2-3
Screw
Wire
saddle
Screws