Installing The Desk Dehumidifier (Service Part) - Kyocera Mita KM-3530 Service Manual

Hide thumbs Also See for KM-3530:
Table of Contents

Advertisement

3CC

1-2-2 Installing the desk dehumidifier (service part)

Desk dehumidifier installation requires the following parts:
Desk dehumidifier (P/N 33960020): for 220 – 240 V specifications only
Desk dehumidifier (P/N 34860030): for 120 V specifications only
Two (2) M4 × 8 S tight screws (P/N B3324080)
Procedure
1. Remove the upper and lower drawers.
2. Remove the three screws holding the desk
rear cover and then the cover.
3. Pass the desk dehumidifier cable to the
machine rear through the cable hole in the
machine right.
4. Attach the desk dehumidifier using the two M4
× 8 S tight screws.
5. Insert the desk dehumidifier connector into the
connector of the main harness.
6. Tidy up the desk dehumidifier cable using the
wire saddle and route the cable while clipping
the wire saddles into the holes in the rear
frame.
7. Refit all removed parts.
1-2-2
M4 × 8 S
tight screws
Desk dehumidifier
cable
Cable hole
Desk dehumidifier
Figure 1-2-2
Wire saddle
Main harness
Figure 1-2-3