Electrical Problems; The Switchback Conveying Motor Does Not Operate; The Switchback Eject Motor Does Not Operate; The Feedshift Solenoid Does Not Operate - Kyocera Mita KM-3530 Service Manual

Hide thumbs Also See for KM-3530:
Table of Contents

Advertisement

3CP

1-3-2 Electrical problems

Problem
(1)
The switchback
conveying motor
does not operate.
(2)
The switchback eject
motor does not
operate.
(3)
The feedshift
solenoid does not
operate.
(4)
The press solenoide
does not operate.
1-3-4
Causes
Broken switchback
conveying motor coil.
Poor contact of the
switchback conveying
motor connector terminals.
Broken switchback eject
motor coil.
Poor contact of the
switchback eject motor
connector terminals.
Broken feedshift solenoid
coil.
Poor contact of the
feedshift solenoid
connector terminals.
Broken press solenoid coil.
Poor contact of the press
solenoid connector
terminals.
Check procedures/corrective measures
Check for continuity across the coil. If none, replace the
switchback conveying motor.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Check for continuity across the coil. If none, replace the
switchback eject motor.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Check for continuity across the coil. If none, replace the feedshift
solenoid.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.
Check for continuity across the coil. If none, replace the press
solenoid.
Reinsert the connector. Also check for continuity within the
connector cable. If none, remedy or replace the cable.

Advertisement