Yamaha 2007 FZ6-NA Service Manual page 489

Table of Contents

Advertisement

minutes after charging is completed
before measuring the open-circuit volt-
age.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
Charging method using a variable-current
(voltage) charger
a. Measure the open-circuit voltage prior to
charging.
NOTE:
Voltage should be measured 30 minutes after
the machine is stopped.
b. Connect a charged and AMP meter to the
battery and start charging.
NOTE:
Set the charging voltage at 16–17 V. If the set-
ting is lower, charging will be insufficient. If too
high, the battery will be over-charged.
c. Make sure that the current is higher than
the standard charging current written on
the battery.
NOTE:
If the current is lower than the standard charg-
ing current written on the battery, set the
charging voltage adjust dial at 20–24 V and
monitor the amperage for 3–5 minutes to
check the battery.
• Reach the standard charging current
Battery is good.
• Does not reach the standard charging cur-
rent
Replace the battery.
d. Adjust the voltage so that the current is at
the standard charging level.
e. Set the time according to the charging time
suitable for the open-circuit voltage.
Refer to "Battery condition checking steps".
f. If charging requires more than 5 hours, it is
advisable to check the charging current
after a lapse of 5 hours. If there is any
change in the amperage, readjust the volt-
age to obtain the standard charging cur-
rent.
g. Measure the battery open-circuit voltage
after leaving the battery unused for more
than 30 minutes.
ELECTRICAL COMPONENTS
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
Charging method using a constant voltage
charger
a. Measure the open-circuit voltage prior to
charging.
NOTE:
Voltage should be measured 30 minutes after
the machine is stopped.
b. Connect a charger and AMP meter to the
battery and start charging.
c. Make sure that the current is higher than
the standard charging current written on
the battery.
NOTE:
If the current is lower than the standard charg-
ing current written on the battery, This type of
battery charger cannot charge the MF battery.
A variable voltage charger is recommended.
d. Charge the battery until the battery's charg-
ing voltage is 15 V.
NOTE:
Set the charging time at 20 hours (maximum).
e. Measure the battery open-circuit voltage
after leaving the battery unused for more
than 30 minutes.
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
6. Install:
• Battery
7. Connect:
• Battery leads
(to the battery terminals)
ECA13630
CAUTION:
First, connect the positive battery lead "1",
and then the negative battery lead "2".
8-116

Advertisement

Table of Contents
loading