Configuring the RibbonMinder
This section explains how to unlock the PROGRAM MODE, find the
RibbonMinder options, make changes, exit the configuration menu, and lock
the PROGRAM MODE.
Following this section is a procedure for changing the Ribbon Size option of
RibbonMinder.
NOTE: All RibbonMinder options are automatically saved in NVRAM
As you perform the following steps, refer to the RibbonMinder menu
diagram shown in Figure 7–1.
RIBBONMINDER
New Ribbon XXX%
Press the ENTER key to reset
ribbon life to 100%.
Fault Action
New Ribbon*
Do Nothing
when selected.
Ribbon Action
Disable*
Display
Fault
Figure 7–1. RibbonMinder Menu Diagram
Ribbon Size
100 Yards*
or Scroll ±
Press Scroll
to adjust size.
1 through 255 Yards
To view options, press:
Scroll
To select an option, press:
To exit the configuration menus
To exit the configuration menus
and return to READY, press:
* = Factory Default
Chapter 7. RibbonMinder
Ribbon Adjust
0*
Press Scroll
or Scroll
± to adjust.
–99% through 99%
Scroll
Enter
Return
Enter
Start
7–3