PC Parallel Interface
The PC Parallel interface (also referred to as the "Centronics" interface)
enables the printer to operate with controllers designed for buffered PC
Parallel printers. The length of the data cable from the host computer to the
printer must not exceed 15 feet (5 meters).
NOTE: For a more reliable data transfer, a maximum cable length of six feet
Table 5–3. Printer PC Parallel Interface Connector Pin Assignments
Input Signals
Signal
DATA LINE 1
Return
DATA LINE 2
Return
DATA LINE 3
Return
DATA LINE 4
Return
DATA LINE 5
Return
DATA LINE 6
Return
DATA LINE 7
Return
DATA LINE 8
Return
DATA STROBE
Return
PAPER INSTRUCTION 15
Return
is recommended.
Output Signals
Pin
Signal
2
ACKNOWLEDGE
20
Return
3
ONLINE/SELECT
21
Fault
4
PAPER EMPTY
22
Return
5
BUSY
23
Return
6
NAUTO FEED
24
7
NINIT (PRIME)
25
8
NOT DATAPRODUCTS*
26
9
EXTERNAL 5 VOLTS
27
1
N SELECT
19
33
Miscellaneous
Pin
Signal
10
CHASSIS GROUND
28
13
GROUND (GND)
32
12
(NC)
30
11
29
14
31
35
18
36
* Used by DP adapter.
Chapter 5. Printer Interfaces
Pin
17
16, 30
34
5–7