Fault
Message
062 EXHAUST FAN FAULT
065 HAMMER BANK FAN FAULT
069 DATA CLEARED
080 POWER SUPPLY HOT
082 POWER SUPPLY 8.5V FAILED
6–18 6400 Line Matrix Printers Setup Guide, Cabinet and Pedestal Models
Operator
Correct-
Explanation
able?
Yes
Sensors cannot detect
current in fan circuit.
Yes
Sensors cannot detect
current in fan circuit.
N/A
Appears when data is
cleared out of printer after
Cancel key has been
pressed.
No
Circuits are overheating on
the power supply board.
No
Internal power failure.
Solution
Power off the printer and remove
paper guide assembly (for
instructions, refer to your 6400
Maintenance Information
Manual). Check that the fan
cable is connected. Check for
obstruction of vents and fan
airway; remove any
obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on the
printer. If this message reoccurs,
contact your IBM service
representative.
NOTE:This message should not
appear on a Pedestal
model. If this message
does appear, contact
your IBM Service
Representative.
Power off the printer and remove
paper guide assembly (for
instructions, refer to your 6400
Maintenance Information
Manual). Check that the fan
cable is connected. Check for
obstruction of vents and fan
airway; remove any
obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on the
printer. If this message reoccurs,
contact your IBM service
representative.
No action necessary.
Contact your IBM service
representative.
Contact your IBM service
representative.