RibbonMinder Menu

RibbonMinder
(from page 110)
New Ribbon
Ribbon
XXX%
Action
Press the ENTER
Display*
key to reset ribbon
Fault Immed.
life to 100%.
Fault Paper Out
Disable
New Ribbon
This provides a means to manually set the printer when a new ribbon has
been installed. The ribbon life displayed on the control panel (if active) sets to
100%. The count internal to the printer also resets, and the tabulation towards
end of ribbon life begins.
Ribbon Action
Display. The factory default for this setting is the DISPLAY mode. When
DISPLAY is selected, the ribbon ink consumption will continually display
on the control panel, decrementing as ink is consumed. When the ribbon
life reaches 0%, the message RIBBON INK OUT/CHANGE RIBBON
displays on the control panel, but the printer continues to accept new print
jobs. No other indication (no flashing light, or warning beep) is given.
Clear the display by replacing the ribbon when NEW RIBBON DETECT is
enabled.
Ribbon
Type
IBM General Purpose Ribbon
60 yds
IBM General Purpose Ribbon
100 yds
IBM High Contrast Ribbon
60 yds
IBM High Contrast Ribbon
100 yds
IBM Premium 2000
90 yds
To view options, press:
To select an option, press:
To exit the configuration menus
and return to READY, press:
* = Factory Default
Print Format Menu
Ribbon End
New Rib.
Point
Detect
Normal*
Enable*
Reduce 5% - 100%
Disable
Extend 100% - 5%
Scroll
Scroll
Enter
Return
Enter
Start