Fault
Message
042 CUSTOM SET DOES NOT EXIST
SAVE FIRST
043 CUSTOM SET ALREADY EXISTS
DELETE FIRST
044 EC FIRMWARE/HARDWARE ERROR
046 EC STOPPED AT STATE
<state>
056 HAMMER COIL OPEN
057 CLOSE PLATEN
058 SHUTTLE JAM
SEE SETUP GUIDE
059 CANCEL PRINT ACTIVE
060 PRINTER HOT
Operator
Correct-
Explanation
able?
Yes
This custom configuration
set does not exist.
Yes
Custom set is
write-protected.
No
Fatal firmware error on the
controller board.
No
Controller self-test and
initialization sequence was
halted at <state>, where
<state> is one of 10
numerically coded
messages.
No
Electrical malfunction of
one or more hammer coils.
Yes
Forms thickness lever is
raised to the open position.
No
No shuttle movement or the
shuttle is moving at the
wrong speed.
N/A
Non-error status message.
No
Controller board sensors
report high temperatures on
the board.
Chapter 6. Routine Service and Diagnostics
Solution
Save the custom set. Refer to
page 3–20, "Saving Your
Configuration in a Custom Set."
Delete existing set, then save
new set. Refer to page 4–19
"Delete Custom Set."
Contact your IBM service
representative.
Contact your IBM service
representative.
(You can continue to print with
degraded print quality.) Contact
your IBM service representative.
Lower the forms thickness lever.
Make sure the ribbon is not
twisted and the forms thickness
lever is set correctly. If the fault
reoccurs, contact your IBM
service representative.
No action necessary.
Contact your IBM service
representative.
6–17