Installing the Hardware
3.
Slide the AC power supply all the way into the slot, firmly but gently pressing to
ensure that the pins on the back of the power supply are completely seated in the
backplane.
4.
Use the #2 Phillips screwdriver to tighten the captive screws on each side of the power
supply to secure it to the chassis.
5.
Attach the power cable to the AC power supply.

Installing a DC Power Supply

The XP DC power supply delivers 3.3, 5, and 12 volts DC to the XP's control module(s),
fan modules, and other components. A single DC power supply provides enough current
to operate a fully-configured chassis.
XP-8000 DC Power Supply
Figure 26
The XP-8000 DC power supply has a three-terminal wiring block on the front panel,
consisting of a positive (+) terminal, negative (-) terminal and a safety ground. The DC
supply is designed to be powered by a 48-volt DC source. You should use 12- to 14-gauge
wire to connect the 48-volt source to the XP-8000 DC power supply. You should use 12- to
14-gauge wire for the safety ground.
54
shows the front view of an XP-8000 DC power supply.
To be installed in a restricted
!
access area in accordance
with the NEC or authority
having jurisdiction.
See manual for installation
PWR
instructions.
48/60V
14A MAX
Figure 26. Front view of an XP-8000 DC power supply