The XP-8600 power supply is somewhat larger than the XP-8000 power supply.
shows the front view of an XP-8600 AC power supply.
The following table lists the specifications for the XP's AC power supply.
Input voltage
Input current (maximum)
To ensure against equipment failure, you can install a redundant power supply. When two
power supplies are active in the XP, they load share, each supply delivering
approximately 50 percent of the current needed. Moreover, if one of the power supplies
fails, the other power supply immediately assumes the entire load, thus preventing any
system outage.
The AC power supply has a green status LED. When the LED is lit, the power supply is
connected to an appropriate power source and is active. The status LED is lit when you
switch the power supply on, not when you plug the power supply into a power source.
Enterasys Xpedition 8000/8600 Getting Started Guide
PWR
G86-PAC
SN
TO REMOVE POWER TO
UNIT DISCONNECT ALL
POWER SUPPLY CORDS
100-125V~ 10A
200-240V~ 6A
50/60 Hz
Figure 5. Front view of an XP-8600 AC power supply
XP-8000
100 to 125, 200 to 240 V AC
5, 3 A
Hardware Overview
Figure 5
XP-8600
100 to 125, 200 to 240 V AC
10, 6 A