The following table lists the environmental specifications for the XP's AC power supplies.
Operating Temperature
Non-operating
temperature
Operating Humidity
Figure 25
following the figure describes how to do this.
SSR-8
AC Power Supply Installation Procedure
To install an AC power supply:
1.
Ensure that the AC power supply is not powered on.
2.
If a cover plate is installed over the power supply slot, use the #2 Phillips screwdriver
to remove it. If you are replacing an AC power supply, unplug the power cable from
the supply you are replacing, loosen the captive screws on the power supply's front
panel, then pull the supply out of the chassis.
Enterasys Xpedition 8000/8600 Getting Started Guide
+5 to +40 °C (41 to 104 °F)
-30 to +73 °C (-22 to 164 °F)
15 to 90% (non-condensing)
shows an example of how to install an AC power supply. The procedure
PWR
G80-PAC
100-125~5A
200-240~3A
50-60 Hz
Figure 25. Installing an AC power supply
Installing the Hardware
53