Troubleshooting - Cleveland OES 6.08 mini Operator's Manual, Use And Care Instructions

Easytouch the mini
Table of Contents

Advertisement

Cleaning and Maintenance

Troubleshooting

Structure of the error message
The following screenshot shows a typical error message to illustrate the layout of all error messages:
Elements of the error messages and their function
The elements of the error messages have the following function:
No.
Name
1
Error number
2
Error code
date
time
3
Description of fault
4
Service number
Errors and required responses
The following table explains the error codes used in the display:
Error
Error
code
code
E01.0
33
E02.0
24
E03
72
E03.0
29
E04.0
36
E11.0
23
E12.1
25
E12.2
26
E12.3
27
E12.4
28
E15.0
21
minis easyTOUCH user manual
Function
Serial number of the detected error (errors are numbered consecutively)
ID number to identify the error
Date on which the error occurred
Time at which the error occurred
Short description of error with error code
Service phone number of manufacturer
Description of fault
Not enough water: Water pressure is less than
0.5 bar 3 seconds after valve activation
Wiring compartment too hot
The secondary fan is turned on at temperatures
> 45°C. The error threshold is 80°C.
Fan fault
Motor thermal protection (bimetal strip) has
tripped
Secondary-fan fault in electrical compartment
Over-temperature detected by oven sensor
Over-temperature detected by core tempera-
ture sensor
Over-temperature detected by condenser
sensor
Required response
1. Open the water supply
2. Contact customer service
1. Clean fluff filter (oven floor)
2. Contact customer service
1. Check fuse
2. Contact customer service
1. Check fuse
2. Contact customer service
Contact customer service
Contact customer service
Correct the sensor position
Contact customer service