ESIE02–01
2.8

Condensation Avoidance Control

Applicable units
FHYP
Operating modes
Regardless of whether the thermostat is ON or OFF, the condensation avoidance control can function
in the following operating modes:
Method
To avoid condensation on the swing flap, the condensation avoidance control is activated:
Stage
1
2
3
4
Part 2 – Functional Description
Cooling (automatic), or
Dry keep.
Description
The fan operates in cooling mode with the blade in downward position (set on the remote
control).
After 30 min, the blade moves to a horizontal position. However, the remote control still
shows the downward position.
After 1 h operation in horizontal position, the blade moves back to its downward position
for 30 min.
The unit operation is reset by:
Changing the operating mode into "heating" or "fan", or
Changing the air flow direction, or
Turning the unit operation ON or OFF.
Overview of the cooling mode functions
1
2
3
4
5
2–35