Chrysler 2004 Concorde Service Manual page 1635

Hide thumbs Also See for 2004 Concorde:
Table of Contents

Advertisement

LH
EGR TUBE - 3.5L (Continued)
INSTALLATION - 3.5L
The EGR tube attaches to the bottom of the intake
manifold plenum beside the throttle body (Fig. 8).
(1) Install rubber silicone seals on intake manifold
end of EGR tube, being careful to be sure silicone
rubber seals is correctly installed and undamaged.
(2) Using a new gasket, loosely install the EGR
tube into the intake manifold and loosely install EGR
tube to EGR valve.
(3) Tighten the EGR tube to EGR valve screws to
11 N·m (95 in. lbs.) torque.
(4) Install clips for the EGR tube to intake mani-
fold plenum (Fig. 9).
(5) Install transmission to throttle body bracket.
(6) Install air inlet tube and resonator.
(7) Connect negative battery cable.
EXHAUST GAS RECIRCULATION 25 - 23
Fig. 9 EGR tube Seal
1 - SILICONE SEAL