Internet: www.cornelius-asia.com E-mail: customerservice@cornelius.com.cn Trademarks and copyrights: Aurora, Cornelius, Decade, Hydro Boost, Olympus, Impulse, Sitco, Spirit, UF-1, Vanguard, Venture, and Vista are registered trademarks of IMI Cornelius. Optifill trademark is pending. This document contains proprietary information and it may not be reproduced in any way without permission from Cornelius.
Vanguard 245 Service Manual TABLE OF CONTENT SAFETY ........................1 Safety Instructions ....................1 Safety Tips ......................1 Authorized Service Personnel ................2 (Carbon Dioxide) Warning ................2 Shipping And Storage ..................3 Equipment Handling ...................3 GENERAL INFORMATION ..................5 General Description ....................5 Unit Description ....................5 Specification .......................7...
Page 4
Vanguard 245 Service Manual TABLE OF CONTENT Source Line (Unit with Integral Carbonator) ........18 Regulators Adjustments ...............18 Adjusting Carbonator CO Regulator ...........18 Adjusting Syrup Supplies CO Regulator ..........18 Fill Water Tank and Start the Refrigeration System ........19 Preparation for Operation ................20...
Page 5
Vanguard 245 Service Manual TABLE OF CONTENT ..................27 Cleaning and Sanitizing ................27 Daily Cleaning of Unit ............28 Sanitizing Post-Mix Syrup Systems ......31 Cleaning Drop-In Refrigeration Assembly Condenser Coil .................32 Checking Ice Water Bath ..................32 Cleaning Water Tank Carbonator Water Pump Yearly Maintenance or After ................34...
Vanguard 245 Service Manual SAFETY AFETY NSTRUCTIONS Read And Follow All Safety Instructions Read and follow all safety instructions in this manual and on the machine (decals, labels, and laminated cards). Read and understand all applicable OSHA (Occupation Safety and Health Administration) safety regulations before operating the machine.
Vanguard 245 Service Manual UTHORIZED ERVICE ERSONNEL CAUTION — Only trained and certified electrical, plumbing and refrigeration technicians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES. ARBON IOXIDE ARNING WARNING -- CO Displaces Oxygen. Strict Attention must be...
Vanguard 245 Service Manual HIPPING TORAGE CAUTION — Before shipping, storing, or relocating the unit, syrup systems must be sanitized and all sanitizing solution must be purged from the syrup systems. All water must also be purged from the plain and carbonated water systems.
This manual is a guide for installing, operating, and maintaining this equipment. This section gives the Unit Description, Theory of Operation, and Design Date for Vanguard 245 Post-Mix Beverage Over Counter Dispenser. This Unit must be installed and serviced by a qualified Service Person. This Unit Contains no User serviceable parts.
Page 12
Removable Refrigeration deck Removable Cladding Removable Drip Tray VANGUARD 245 DISPENSER (EIGHT-FLAVOR UNIT SHOWN) The Vanguard 245 over the counter, post-mix, beverage dispenser offers the following features: • Six or eight valves • Built-in carbonator (optional) • Removable refrigeration deck •...
Vanguard 245 Service Manual CAPABILITY Dispensing rate : 12 OZ. drinks 4 / min. or fewer 1000 * NOTE: Number of drinks dispensed 4° C ( 40° F ) or below @ 24 ° C ( 75° F ) syrup and water inlet temperature and 24° C ( 75° F ) ambient.
Page 15
Vanguard 245 Service Manual UNIT WITH INTEGRAL CARBONATOR NOTE: The unit is factory set to dispense non-carbonated water and carbonated water as per customer’s requirement. It is available to dispense at most 2 non-carbonated waters ( 6 Flavours ) or 3 non-carbonated waters ( 8 Flavors ) with carbonated water dispensing from the remaining valve(s).
Vanguard 245 Service Manual INSTALLATION CAUTION — Only trained and certified electrical, plumbing and refrigeration technicians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES. ELIVERY NSPECTION AND NPACKING INSPECTION Upon delivery inspect the unit for damage or irregularities and immediately report problems to the delivering carrier and file a claim with that carrier.
Vanguard 245 Service Manual DENTIFICATION OF OOSE- HIPPED ARTS 1. Drip tray brackets to be installed on the unit, then drip tray to be installed on the drip tray brackets and secured with screws, thread cutting. Cup rest is then to be installed in the drip tray.
Vanguard 245 Service Manual CAUTION: Do not place or store anything on top of the Unit. 2. Clearance above top of the Unit must be open to the ceiling. A minimum clearance of 300 mm (12 inches) must be maintained on the back side of the Unit and a minimum of 150 mm (6 inches) clearance to the nearest obstruction must be maintained on both sides of the Unit.
Page 20
Vanguard 245 Service Manual 5. Out Unit base back access hole - Route water tank drain hose, drip tray drain hose, and water tank overflow hose out Unit base back access hole. The carbonated water, plain water, and the syrup inlet lines that are to be connected to the Unit will be routed through the back access hole up to the front of the Unit for connection to the stainless-steel inlet tubes.
Vanguard 245 Service Manual INSTALLING WATER LEVER KITS The water lever kits are loose-shipped only with dispenser’s equipped with UF-1 dispensing valves. The water lever kits may be installed on dispensing valves to dispense plain or carbonated water only. Refer to instructions included with the kits for installation instructions.
Unit. CONNECTING PLAIN WATER SOURCE LINE TO UNIT NOTE: IMI Cornelius Inc; recommends that a water shutoff valve and a water filter be installed in the plain water source to be connected to the Unit. The plain water source water pressure must not be less than 35-psi or more than 45-psi.
Vanguard 245 Service Manual CONNECTING CO SOURCE LINE (UNIT WITH INTEGRAL CARBONATOR) Proceed as follows to connect CO source line to Unit with integral (built-in) carbonator. 1. Route CO source line, connected to an adjustable CO regulator, up to the Unit.
Vanguard 245 Service Manual FILL WATER TANK AND START THE REFRIGERATION SYSTEM 1. Make sure plug in end of the water tank drain hose is secure. NOTE: Use a low-mineral-content water where a local water problem exists. 2. Remove plug from drop-in refrigeration assembly platform water fill hole. Fill the water tank with clean water until water flows out of the water tank overflow hose.
Vanguard 245 Service Manual PREPARATION FOR OPERATION 1. Unit requiring connection to a remote carbonator–Activate plain water and carbonated water supplies to the Unit. 2. Place dispensing valves keyed lock-out switch on side of the Unit in the ‘‘ON’’ position.
Vanguard 245 Service Manual OPERATOR’S INSTRUCTIONS WARNING: Disconnect electrical power to the Unit to prevent personal injury before attempting any internal maintenance. Only qualified personnel should service the internal components or electrical wiring. CAUTION: Do not place or store anything on top of unit.
Vanguard 245 Service Manual DISPENSING VALVES KEYED LOCK-OUT SWITCH The dispensing valves keyed lock-out switch, located on side of the Unit must be in the “ON” (vertical) position to operate the electric dispensing valves. The keyed lock-out switch in the “OFF” (horizontal) position turns off electrical power to the dispensing valves only but the refrigeration system will continue to operate.
Vanguard 245 Service Manual CHECKING DROP-IN REFRIGERATION ASSEMBLY CONDENSER COIL FOR RESTRICTIONS CAUTION: Circulating air, required to cool the refrigeration assembly condenser coil, is drawn in through grille on back of the hood and is exhausted out through grille on top of the hood. Restricting air in or out of the Unit will decrease the refrigeration system cooling efficiency.
Vanguard 245 Service Manual UNIT WITH INTEGRAL (BUILT-IN) CARBONATOR The water pump water strainer screen and the liquid double check valve must be inspected and cleaned as instructed at least once a year under normal circumstances and after any water system disruption (plumbing work, earthquake, etc.). Refer to SERVICE AND MAINTENANCE section of this manual for inspecting and cleaning procedure.
Vanguard 245 Service Manual SERVICE IMPORTANT: Only qualified personnel should service the internal components or electrical wiring. WARNING: Disconnect electrical power from the Unit to prevent personal injury before attempting any internal maintenance. Only qualified personnel should service the internal components or electrical wiring.
Vanguard 245 Service Manual PERIODIC INSPECTION 1. Clean the drop-in refrigeration assembly condenser coil every 30-day as instructed in this manual section. Cleaning the condenser coil should be performed by a qualified Service Person. DO NOT place objects on top of or on back side of the Unit hood.
Vanguard 245 Service Manual SUGAR SYRUP TANKS CO REGULATOR Adjust syrup tanks CO regulator to a minimum of 45-psi. Low-calorie (Diet) Syrup Tank CO Regulator Adjust low-calorie (diet) syrup tank secondary CO regulator to 10-psi for syrup lines up to 30-feet in length. Syrup lines longer than 30-feet in length may require a slightly higher setting of 12-psi maximum.
Vanguard 245 Service Manual 5. Remove nozzle and syrup diffusers from the dispensing valves. Place nozzles and syrup diffusers in sanitizing solution. 6. Wash the nozzles and syrup diffusers in sanitizing solution, then rinse them with potable water. 7. Re-install nozzles and syrup diffusers back on the dispensing valves.
Page 35
Vanguard 245 Service Manual C. Continue to activate the dispensing valve in cycles (“ON” for 15-seconds, “OFF”, then “ON” for 15-seconds). Repeat “ON” and “OFF” cycles for 15-cycles. 6. Connect detergent solution to the remaining syrup systems and flush syrup out of the syrup systems as instructed in step 5 preceding.
Page 36
Vanguard 245 Service Manual 13. Syrup Tank Systems Connect sanitizing solution tank, pressurized at 60 to 80-psi, into one of the syrup systems. Bag-in-Box Syrup System Place all bag-in-box syrup containers syrup outlet tubes in container containing sanitizing solution. 14. Sanitize the syrup system and dispensing valve as follows: A.
Vanguard 245 Service Manual C. Continue to activate the dispensing valve in cycles (“ON” for 15-seconds, “OFF”, then “ON” for 15-seconds). Repeat “ON” and “OFF” cycles for 15-cycles. 21. Repeat steps 19 and 20 preceding to purge sanitizing solution out of the remaining syrup systems and dispensing valves.
Vanguard 245 Service Manual 1. Disconnect electrical power from the Unit. 2. Remove screw securing the hood, then lift the hood straight up to remove from the Unit. 3. Vacuum or use a soft brush to clean the condenser coil. If available, use low-pressure compressed air.
Page 39
Vanguard 245 Service Manual B. Disconnect carbonated water tank ground wire (green with yellow stripe) connector, protruding up B. Disconnect carbonated water tank ground wire (green with yellow stripe) connector, protruding upthrough hole in drop-in refrigeration assembly deck, from mating ground wire connector on top of the refrigeration assembly deck.
Vanguard 245 Service Manual A. Referring to previous IMPORTANT note, very carefully, lower drop-in refrigeration assembly down into the Unit lower housing. Make sure carbonated water tank ground wire connector is routed up through hole in the refrigeration assembly deck.
Vanguard 245 Service Manual UNIT WITH INTEGRAL (BUILT-IN) CARBONATOR The carbonator water pump water inlet strainer screen and double liquid check valve must be inspected and cleaned at least once a year under normal circumstances and after any water system disruption (plumbing work, earthquake, etc.). This service procedure must be performed by a qualified Service Person.
Page 42
Vanguard 245 Service Manual 4. Wipe each part with clean lint–free cloth. Inspect each part, especially the ball for burrs, nicks, corrosion, deterioration, and other damage. Discard ball seat and any damaged or suspicious parts and replace with new parts during reassembly.
Vanguard 245 Service Manual LEANING CO YSTEM HECK ALVES The CO regulators CO gas check valves and the Unit CO inlet line CO gas check valve must be inspected and serviced at least once a year under normal conditions and after any servicing or disruption of the CO system.
Vanguard 245 Service Manual TROUBLE SHOOTING IMPORTANT Only a service person should service internal components or electrical wiring. IMPORTANT If repairs are to be made to one of the syrup circuits, disconnect applicable syrup tank and bleed pressure from the system before proceeding.
Page 46
Vanguard 245 Service Manual TROUBLESHOOTING UNIT Trouble Probable Cause Remedy Only syrup dispensed. 1. Remote Carbonator Unit 1. Open plain water inlet Plain water inlet supply line supply line shutoff valve. shutoff valve closed. Carbonator not operating. Refer to manual provided with carbonator.
Page 47
Vanguard 245 Service Manual TROUBLESHOOTING UNIT Trouble Probable Cause Remedy Adjustment of dispensing 1. Dirty or inoperative 1. Disassemble and valve syrup flow regulator dispensing valve syrup clean dispensing does not decrease to desired flow control. valve syrup flow water-to-syrup ratio.
Page 48
Vanguard 245 Service Manual TROUBLESHOOTING UNIT Trouble Probable Cause Remedy Dispensed product 1. Recovery rate of refrigeration of 1. Allow ice bank to produces foam as it system exceeded, ice bank recover. leaves dispensing depleted. valve. 2. Primary CO regulator pressure 2.
Page 49
Vanguard 245 Service Manual TROUBLESHOOTING UNIT Trouble Probable Cause Remedy No product dispensed. 1. Dispensing valves keyed 1. Place keyed lock-out lock-out switch in “OFF” switch in “ON” position. position. 2. No electrical power to 2. Plug in dispenser power dispenser.
Vanguard 245 Service Manual TROUBLESHOOTING REFRIGERATION SYSTEM Trouble Probable Cause Remedy Refrigeration 1. Ice bank sufficient. 1. No refrigeration called for. compressor does 2. No water in water 2. Fill water tank with water as not operate. tank. instructed. 3. Control board power 3.
Page 52
Vanguard 245 Service Manual TROUBLESHOOTING REFRIGERATION SYSTEM Trouble Probable Cause Remedy Compressor will not stop 1. Ice bank probe location 1. Place probe in proper after sufficient ice bank is incorrect. location. produced. 2. Ice temperature sensor 2. Replace ice temperature inoperative.
Vanguard 245 Service Manual COMPONENT SERVICE The following are procedures for replacing the major components of the Vanguard. ARBONATOR EPLACEMENT 1. Shut off water and CO at their sources. 2. Remove the hood by removing screws on the top and lifting up.
Vanguard 245 Service Manual OTOR EPLACEMENT 1. Shut off water and CO at their sources. 2. Remove the hood by removing screws on the top and lifting up. 3. Depressurize carbonator by dispensing drinks from any valve. 4. Disconnect power to the unit.
Vanguard 245 Service Manual GITATOR OTOR EPLACEMENT 1. Disconnect power to the unit. 2. Shut off water and CO at their sources. 3. Remove the hood by removing screws on the top and lifting up. 4. Remove carbonator cover by removing mounting bolts and lifting up.
Vanguard 245 Service Manual ONTROLLER OARD EPLACEMENT 1. Shut off water and CO at their sources. 2. Remove the hood by removing screws on the top and lifting up. 3. Remove controller cover by following, • remove mounting screw •...
Page 57
Vanguard 245 Service Manual ONDENSER OTOR EPLACEMENT 1. Shut off water and CO at their sources. 2. Remove the hood by removing screws on the top and lifting up. Mounting 3. Disconnect power to the unit. screws of cover 4. Remove cover by removing two mounting screws.
Page 65
Vanguard 245 Service Manual ILLUSTRATED PARTS LIST VANGUARD 245 POST-MIX DISPENSER (COLD CARBONATED) Item Item Part No. Names Part No. Names Pump and Mot. Assy. 230 V 60HZ 3600 Blade Agit. Pump and Mot. Assy. 230 V 50HZ 186610000 Pin Sprg 200498003 Nut Hex No.
Page 66
Vanguard 245 Service Manual ILLUSTRATED PARTS LIST VANGUARD 245 POST-MIX DISPENSER (COLD CARBONATED) FIGURE 5. PUMP AND MOTOR (COLD CARB) ASSEMBLY Item Item Part No. Names Part No. Names Pump and Motor 230V 60HZ 313438000 Switch Toggle Pump and Motor 230V 50HZ 3175 Harn Wire Carb.
Page 68
Vanguard 245 Service Manual REFERENCE MATERIAL IAGRAM Six-Flavor Unit Requiring Remote Carbonator DISPENSING VALVE(6) DUAL CARB WATER COOLING COILS(5) CARB DRINK CO2 WATER 1 SYRUP 1 SYRUP COOLING CARB DRINK COILS(6) CO2 WATER 2 SYRUP 2 STILL PLAIN WATER (NON-CARB)
Page 69
Vanguard 245 Service Manual REFERENCE MATERIAL IAGRAM Eight-Flavor Unit Requiring Remote Carbonator DISPENSING VALVE(8) DUAL CARB WATER COOLING COILS(4) CARB DRINK CO2 WATER 1 SYRUP 1 SYRUP COOLING STILL COILS(8) CO2 / PLAIN WATER 2-3 (NON-CARB) OR CARB DRINK SYRUP 2...
Page 72
Release Date: July 2006 Publication Number: 301135000E Visit the IMI Cornelius Web Site at www.cornelius-asia.com for all your Literature needs. This manual is apply for equipment series no. from 89E0630VDXXX. IMI CORNELIUS ( TIANJIN ) CO., LTD...