Front Panel Menus - At a Glance

ADDRESS 7
Address
ô
INTF GPIB
ô
BAUDRATE 300
ô
PARITY NONE
ô
FLOW NONE
ô
LANG SCPI
*RCL 0
Recall
*SAV 0
Shift
Save
ERROR 0
Shift
Error
12.000V 0.204A
Meter
ô
12.500V MAX
ô
1.000V MIN
ô
12.330V HIGH
ô
0.080V LOW
ô
12.000V RMS
ô
0.350A MAX
ô
0.050A MIN
ô
0.400A HIGH
ô
0.012A LOW
ô
0.210A RMS
VOLT 20.000
Voltage
CURR 2.000
Current
OC -- -- -- --
Protect
*RST
Output
ô
PON:STATE RST
ô
PROT:DLY 0.08
ô
RI LATCHING
ô
DFI OFF
ô
DFI:SOUR OFF
ô
PORT RIDFI
ô
DIGIO 7
ô
RELAY ON
ô
RELAY NORM
VOLT:PROT 22
Shift
OV
CURR:RANG HIGH
Shift
Input
ô
CURR:DET ACDC
CAL ON
Cal
Shift
Ì
Ë
Use
and
to select menu parameters. Use
1
Not available on Agilent 6631B - 6634B or in Compatibility mode.
Sets the GPIB Address
Selects an interface (GPIB or RS232)
Selects baud rate (300, 600, 1200, 2400, 4800, 9600)
Selects message parity (NONE, EVEN, ODD, MARK, SPACE)
Selects flow control (XON-XOFF, RTS-CTS, DTR-DSR, NONE)
Selects language (SCPI or COMP)
Recalls instrument state
Saves present instrument state
Displays errors in SCPI error queue
Measures output voltage and current
Measures peak output voltage
Measures minimum output voltage
Measures the high level of a voltage pulse waveform
Measures the low level of a voltage pulse waveform
1
Measures rms voltage
Measures peak output current
Measures minimum output current
Measures the high level of a current pulse waveform
Measures the low level of a current pulse waveform
1
Measures rms current
Sets the output voltage
Sets the output current
Protection status (example shows overcurrent tripped)
Places the dc source in the factory-default state
Select the power-on state command (RST or RCL0)
Sets the output protection delay in seconds
Sets the remote inhibit mode (LATCHING, LIVE, or OFF)
Sets the discrete fault indicator state (ON or OFF)
Selects the DFI source (QUES, OPER, ESB, RQS, or OFF)
Sets the output port functions (RIDFI or DIGIO)
Sets and reads the I/O port value (0 through 7)
Sets the output relay state (ON or OFF)
Sets the output relay polarity (NORM or REV)
Sets overvoltage protection level
Sets current range (HIGH, LOW, or AUTO)
Sets current measurement detector (ACDC or DC)
Accesses calibration menu (See User's Guide).
to exit any menu and return to metering mode.
Meter
2
Not available on Agilent 6631B.
Quick Reference – 1
1
1
1
1
1
1
1
1
2
2
1
13